The aluminum-plastic composite tape should be tightly wound on the steel or equivalent pipe core, the inner diameter of the pipe core should be 100mm+/-2mm, 150mm+/-2mm, 204mm+/-mm, 406mm+/-mm.The tube core length of the slitted aluminum plastic composite tape should be the same as the width of the aluminum plastic composite tape. The tube core protruding from the end face of the composite tape should be less than 1mm. The tube core length of the unslitted aluminum plastic composite tape should exceed the side of the composite tape by 5-10mm.
Technical Indicator:
No. | Item | Requirement | |
1 | Tensile strength Mpa | ≥300 | |
2 | Elongation at break % | ≥15 | |
3 | Stripping strength between steel tape and coating N/cm | ≥6.13 | |
4 | Shear strength of thermal zone for EGE | EGE broken or cohere destroyed between film and tape, but no shearing destroyed in thermal zones | |
5 | Thermal sealing strength N/cm | ≥17.5 | |
6 | Water proof(68 ±1℃,168h)N/cm | ≥6.13 | |
7 | The filling compound resistance(68±1℃,168h) | No delamination between steel tape with plastic film | |
8 | Corrosion resistance(0.1mol/1,NaOH,480h) | ≥7级 | |
9 | Dielectric strength | Single face EGE,1kVd.c.1min | Not breakdown |
Double face EGE,2kVd.c.1min | Not breakdown |
FAQ
Q: Would you provide samples For free?